Welcome to Kaizen Airtreat Pvt Ltd!
We'are Open: Mon - Sat 10:00 AM - 7:00 PM
Comprises Air Handling Unit System
Comprises Air Handling Unit System

Comprises Air Handling Unit System

Price 8000 INR/ Piece

MOQ : 10 Pieces

Comprises Air Handling Unit System Specification

  • Power Consumption
  • Depends on unit size (typically 1.5-15 kW)
  • Noise Level
  • <70 dB
  • Air Discharge
  • Side/Top/Bottom Discharge Options
  • Condition
  • New
  • Material
  • Galvanized Steel / Mild Steel
  • Power Source
  • Electric
  • Voltage
  • 220-415V AC
  • Dimensions
  • Customized as per requirement
  • Lubrication Type
  • Automatic lubrication
  • Configuration
  • Horizontal/Vertical
  • Mute
  • Low vibration design
  • Air Flow Capacity
  • 2000 to 35000 CFM
  • Driven Method
  • Belt Driven or Direct Drive
  • Working Presssure
  • 500 - 2000 Pa
  • Motor
  • High efficiency electric motor
 

Comprises Air Handling Unit System Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 1-8 Days
 

About Comprises Air Handling Unit System

We are offering a wide array of Comprises Air Handling Unit System. It comprises a large insulated metal box that contains cooling and humidity. This system is the most important factor to maintain the required Class. It is the heart of clean room system as well as heart of ventilation system. Comprises Air Handling Unit System is popular in assembly plants, automobile industry, dust free paint room and so on. It comes at cost effective prices. 

Specification

Power Source

Electric

Surface Finish

Powder Coated

Material

Mild Steel

Brand

Kaizen

Frequency

50 Hz

Installation Type

Wall mounted

Voltage

230V

Usage/Application

Industrial Use

 



Advanced Filtration & Air Quality

Our AHU system utilizes multiple filter types, including pre-filter, fine filter (EU4, EU7), and HEPA options made from synthetic fiber, ensuring effective removal of particulates and contaminants. This comprehensive filtration system helps maintain clean, fresh air in hospitals, cleanrooms, and sensitive industrial environments.


Flexible & Durable Construction

Constructed from galvanized or mild steel and finished with corrosion-resistant powder coating, the AHUs are designed for lasting performance. Modular sections allow customization between 2 to 8 units, while frame thickness (1.2-2 mm) and reinforced insulation options (PUF or Rockwool) support diverse installation needs.


Quiet, Energy-Efficient Operation

Equipped with high-efficiency electric motors, centrifugal or plug fans, and a low-vibration design, our AHUs deliver powerful airflow from 2,000 to 35,000 CFM with noise levels below 70 dB. Automatic lubrication and variable drive methods (belt/direct) reduce maintenance and promote reliable performance while optimizing power consumption.

FAQ's of Comprises Air Handling Unit System:


Q: How does the air handling unit system ensure effective air filtration in hospitals and cleanrooms?

A: The system uses a combination of pre-filters, fine filters (EU4/EU7), and HEPA filters made from synthetic fibers to capture particulates of various sizes. This layered filtration effectively removes dust, bacteria, and airborne contaminants, supporting stringent air quality standards essential for hospitals and cleanrooms.

Q: What are the options for configuring the Air Handling Unit to match my facility's needs?

A: Our AHU offers modular construction with 2 to 8 sections, customizable insulation thickness (25mm/50mm PUF or Rockwool), various filter grades, horizontal or vertical installation, and multiple air discharge positions (side, top, bottom), ensuring adaptability to specific site requirements.

Q: When is humidity control recommended for the AHU system?

A: Humidity control, using optional humidifiers or dehumidifiers, is recommended when precise indoor air moisture levels are necessary, such as in cleanrooms, laboratories, and certain manufacturing environments that require regulated humidity for optimal operation and product quality.

Q: Where can the AHU system be installed, and what mounting options are available?

A: The AHUs are suitable for a variety of locations, including commercial buildings, industrial sites, hospitals, and cleanrooms. They can be floor mounted or suspended based on installation requirements and spatial constraints.

Q: What is the process for maintaining the AHU system and its components?

A: Routine maintenance includes checking and replacing filters, inspecting fan systems and heat exchangers for build-up or corrosion, monitoring the control panel settings, and ensuring automatic lubrication systems are functioning. Full-length hinged access doors with air-tight gaskets make inspections simple and efficient.

Q: How does the AHU benefit building occupants and operations?

A: By delivering clean, conditioned air, reducing noise (<70 dB), and maintaining optimal temperature and humidity, the AHU system creates a healthy and comfortable environment. Its robust design and anti-corrosive treatments also minimize downtime and repair costs, enhancing operational reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email